CDLZY - 229H9502, DEVRAN 229 ACRYLIC EPOXY GLOSS (SUPP DATA)
- MSDS: CDLZY
- Manufacturer: DEVOE COATINGS CO
- Product Name: 229H9502, DEVRAN 229 ACRYLIC EPOXY GLOSS (SUPP DATA)
- National Stock Number: 8010-00N030002
Product Identification
Product ID:229H9502, DEVRAN 229 ACRYLIC EPOXY GLOSS (SUPP DATA)
MSDS Date:09/19/1995
FSC:8010
NIIN:00N030002
Kit Part:Y
MSDS Number: CDLZY
Responsible Party
LOUISVILLE, KY 40207
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 502-897-9861
Cage: 1HK86
Contractor
Telephone: 502-897-9861
Cage: 1HK86
Ingredients
LG QTYS IN BLDGS TO COMPLY W/OSHA 1910.106. KEEP
RTECS: 9999999ZZ
BOTTLES/OTHER UNLABELED CNTNRS. DO NOT REUSE EMPTY
RTECS: 9999999ZZ
MIXT OF BASE & CONVERTER PORTIONS WILL HAVE HAZARDS
RTECS: 9999999ZZ
FILTER DESIGNED TO REMOVE DECOMP PARTICULATES &
RTECS: 9999999ZZ
SUPPLY RESPS/HOODS. USE NIOSH APPRVD CHEM RESP WHEN
RTECS: 9999999ZZ
MIXING, APPLICATN & CURING AREAS & TO REMOVE SANDING
RTECS: 9999999ZZ
& FLAME CUTTING ON SURFS COATED W/THIS PROD. VAPS
RTECS: 9999999ZZ
SOLVENT VAPORS FROM LOWER LEVELS OF THE WORK AREA.
RTECS: 9999999ZZ
1. MFR CAS #
CAS: 142-92-7
RTECS: AT0875000
Fraction By Weight: 15%
OSHA PEL N/K
ACGIH TLV: N/K
ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA).
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 20%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM;200 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
BUTYL ALCOHOL; (N-BUTYL ALCOHOL) (SARA 313) (CERCLA).
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: 5%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM, S, C
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER;(PROPYLENE
CAS: 108-65-6
RTECS: AI8925000
Fraction By Weight: 15%
OSHA PEL N/K
ACGIH TLV: N/K
(ORAL,RAT) >5
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: <5%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE, 1-CHLORO-2, 3-EPOXY-; (EPICHLOROHYDRIN) (SARA
CAS: 106-89-8
RTECS: TX4900000
OSHA PEL 5 PPM, S
ACGIH TLV: 2 PPM, S
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
BEYOND CLSD DOORS. DUE TO PRESS BUILD-UP, CLSD
RTECS: 9999999ZZ
WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMPTY) AS
RTECS: 9999999ZZ
OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS
RTECS: 9999999ZZ
TOLUENE APPEARS ON
RTECS: 9999999ZZ
FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ
RTECS: 9999999ZZ
IMMED. DO NOT INDUCE VOMIT. ASPIR OF MATL
RTECS: 9999999ZZ
OF VAPS BY MAINTAINING CONTINUOUS FLOW OF FRESH
RTECS: 9999999ZZ
ACRYLIC RESIN
Fraction By Weight: 25%
OSHA PEL N/K
ACGIH TLV: N/K
EPOXY RESIN
CAS: 25068-38-6
RTECS: KC2100000
Fraction By Weight: 10%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:IRRIT OF RESP TRACT; HDCH,
NAUS, DIZZ, WEAK & FATG. EXTREME EXPOS CAN RSLT IN UNCON & EVEN
RESP ARREST. SKIN/EYE CONT:CAUSE IRRIT. MAY BE HARMFUL IF ABSORBED
THRU SKIN. INGEST:CAN CAUSE ST OM &/OR INTEST IRRIT, NAUS, VOMIT &
DIARR. CHRONIC:RPTS HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:EPICHLOROHYDRIN:IARC MONOGRAPHS, SUPP,
VOL 7 PG 202, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON CARCINS,
1994:ANTIC TO (SUPDAT)
Effects of Overexposure:HLTH HAZ:W/PERM BRAIN & NERV SYS DMG.
PRLNG/RPTD BRTHG OF SPRAY MIST &/OR SANDING DUST OVER A PERIOD OF
YRS MAY CAUSE DUST DISEASE OF THE LUNGS. NOTICE:INTENTIONAL MISUSE
BY DELIB CONC & INHAL CONTENT S MAY BE HARMFUL/FATAL. WARNING:THIS
PROD CNTNS CHEM KNOWN TO STATE OF CALIFORNIA TO CAUSE BIRTH
DEFECTS, OTHER (ING 14)
Medical Cond Aggravated by Exposure:NONE, WHEN USED I/A/W SAFE HANDLING
& USE INFORMATION.
First Aid
First Aid:INHAL:IF YOU EXPER DFCLTY IN BRTHG, LEAVE AREA TO OBTAIN
FRESH AIR. IF CONTINUED DFCLTY IS EXPER, SUMMON MED ASSISTANCE
IMMED. IF BRTHG CEASES, RESTORE USING APPRVD CPR TECHNIQUES &
SUMMON HELP IMMED. EYES:FLUSH IMMED W/LG AMTS OF WATER FOR AT LST
15 MINS. GET MED ATTN. SKIN:WASH AFFECTED AREAS W/SOAP & WATER.
REMOVE SOILED CLTHG. GET MED ASSISTANCE IF IRRIT PERSISTS.
INGEST:CONSULT MD (ING 16)
Fire Fighting
Flash Point Method:SCC
Flash Point:80.0F,26.7C
Lower Limits:1%
Extinguishing Media:IN CASE OF FIRE USE CO*2, DRY CHEMICAL, FOAM OR
OTHER NFPA APPROVED METHOD FOR TREATING A CLASS B FIRE.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
SUMMON PROFESSIONAL FIREFIGHTERS. WATER SPRAY MAY BE INEFT. IF
WATER IS USED, FOG NOZZ PREF. IF EXPOS TO(SUPDAT)
Unusual Fire/Explosion Hazard:FLAMM LIQ-CLASS IC. KEEP CNTNRS TIGHTLY
CLSD. ISOLATE FROM HEAT, ELEC EQUIP, SPKS & FLAME. VAPS MAY CAUSE
FLASH FIRE, IGNIT EXPLO & SPREAD LONG DISTS & (ING 11)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT SURFS
& ELEC, STATIC/FRICTIONAL SPKS). PVNT BRTHG OF VAPS. VENT AREA.
BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZ CAUT INFO IN OTHER
SECTIONS OF THIS MSDS. CONTAI N SPILLED MATL & REMOVE W/INERT
ABSORB & (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT BREATHE VAPS, SPRAY
MIST/SANDING DUST. DO NOT GET ON SKIN/IN EYES. KEEP AWAY FROM HEAT,
SPKS & FLAMES. DO NOT SMOKE. OBSERVE ALL APPLIC PRECS.
Other Precautions:EXTING ALL PILOT LIGHTS & TURN OFF ALL SOURCES OF
IGNIT INCL HEATERS, FANS & OTHER NON-EXPLO-PROOF ELEC EQUIP, DURING
USE & UNTIL ALL VAPS ARE GONE. VAPS MAY IGNITE EXPLOSIVELY & SPREAD
LONG DISTS & B EYOND CLSD DOORS. PVNT BUILD-UP (ING 17)
Exposure Controls
Respiratory Protection:WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS &
DURING SANDING/GRINDING OPERATIONS, USE NIOSH APPRVD MECH FILTER
RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY & SANDING
DUST. WHEN USED IN RESTRICTED VENT AREAS, WEAR NIOSH APPRVD
(SUPDAT)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONC BELOW CURRENT APPLIC SFTY & HLTH STDS IN (ING 23)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . SOLV IMPERMEABLE CLTHG & BOOTS TO PREVENT SKIN CONTACT ARE
REC.
Work Hygienic Practices:REMOVE & WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:COATING - NEUTRAL TINT BASE. FIRE FIGHT
PROC:FIRE/EXTREME HEAT, WATER SHOULD BE USED TO COOL CLSD CNTNRS &
PVNT PRESS BUILD UP/POSS AUTO-IGNIT. EXPLAN OF CARCIN:BE CARCIN.
HUM AN:RESP CANCER. SPILL PROC:NON-SPKING TOOLS. STORE IN CLSD
CNTNR UNTIL PROPERLY DISP OF. RESP PROT:CHEM/MECH (ING 21)
Chemical Properties
Boiling Pt:B.P. Text:>244F,>118C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.99
VOC Pounds/Gallon:563
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:63.8
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.